There are many innovations in low parameter single pressure, dual pressure or flash evaporation, medium parameter super heating and other technologies. Combined with the difference between the generator system and the air extraction system, a pure waste heat power generation system can be built for users according to kiln conditions and local conditions. The main technical indicators are as follows:
Air temperature at boiler inlet: 360-420℃
Flue gas flow: 0.7-1.0Nm3/kg-cl
Settling chamber resistance: <310Pa
Dedusting efficiency: >70%
Main steam parameters:1.5-1.7MPa@360-380℃
Thermal efficiency of waste heat power generation system: ≥22%
Power generation: 36-40kwh/t-cl